Manufacture · Supply · Installation across South Africa
White River, Mpumalanga +27 76 118 2117 sales@capstonefencing.co.za
Concrete palisade fencing technical system

Concrete palisade fencing specifications—made clear.

Realistic product visualization and controlled technical guidance for Capstone’s 1.8 m and 2.4 m reinforced concrete palisade assemblies, including razor-flatwrap options.

Close technical view of a reinforced concrete palisade post, crossbars, bolted pales and reinforcement
Product + controlled dimensions

See the reinforced bay, then read the specification.

The realistic render explains the assembled product. The controlled elevation preserves two-metre post centres, nine pales, two crossbars and the standard quotation-stage footing basis.

Illustrative reinforced concrete palisade fence bay with nine pales and two crossbars CP–R01 Illustrative product render
System visualComplete reinforced concrete palisade bay

A visual interpretation of the post, crossbar, nine-pale, fixing, footing and optional plinth relationship. Use the controlled data below for project comparison and quotation.

  • 2 000 mm centres
  • Exactly 9 pales
  • 2 reinforced crossbars
  • 1.8 / 2.4 m systems
CP–01Concrete palisade bay

Quotation-stage elevation · not for construction

FRONT ELEVATIONPost + crossbar + pale assembly
Concrete palisade bay and standard foundation elevation A two metre bay with two posts, nine reinforced pales, two crossbars and quotation-stage foundations. 2 000 mm CENTRES 1.8 / 2.4 m 9 PALES / BAYCROSSBARFOUNDATION
01Bay format2 000 mm centres

Nine reinforced pales per standard section.

02Structure2 crossbars

Reinforced concrete rails with nine 8 mm holes.

03Fixing8 mm bolts

Top and bottom fixing for every pale.

04Foundation basis450 × 450 × 600

Minimum 15 MPa concrete; final detail is site-specific.

Designed from Capstone’s supplied specification. Reinforcement and product strength details appear below; final foundation and loading requirements remain project-specific.
CP / COMPONENTSReinforced concrete assembly

Component-level technical view

150 × 220 → 80 mm 95 × 75 → 75 mm 1 950 × 75 × 140 mm POST4 × 5.5 mm rods PALE3 × 5.5 mm rods CROSSBAR2 × 5.5 mm rods · 9 holes
Inside the system

Designed as an assembly.

Each two-metre bay combines two posts, nine reinforced pales, two reinforced crossbars and top-and-bottom fixings.

Bay format2 000 mm post centres
Vertical members9 reinforced pales
Horizontal members2 reinforced crossbars
Fixings8 mm pale fixing bolts, top and bottom
Product strength20–34 MPa depending on curing period
Configuration matrix

Four documented systems.

Compare fence height, total post length and the razor-flatwrap option. The grid below replaces four near-illegible page thumbnails.

CP-18Standard system
1 800 mm fence 9 PALES · 2 CROSSBARS · 2 000 mm CENTRES
CP-18

1.8 m standard

Fence
1 800 mm
Total post
2 400 mm
Top detail
No razor flatwrap
Download source specification
CP-18RRazor addition
1 800 mm fence 9 PALES · 2 CROSSBARS · 2 000 mm CENTRES
CP-18R

1.8 m + flatwrap

Fence
1 800 mm
Total post
2 900 mm
Top detail
500 mm flatwrap
Download source specification
CP-24Standard system
2 400 mm fence 9 PALES · 2 CROSSBARS · 2 000 mm CENTRES
CP-24

2.4 m standard

Fence
2 400 mm
Total post
3 000 mm
Top detail
No razor flatwrap
Download source specification
CP-24RRazor addition
2 400 mm fence 9 PALES · 2 CROSSBARS · 2 000 mm CENTRES
CP-24R

2.4 m + flatwrap

Fence
2 400 mm
Total post
3 600 mm
Top detail
500 mm flatwrap
Download source specification
CP / SITE DETAIL 600 deep 450 × 450 500 flatwrap
Foundation + security detail

What happens below and above the fence.

The supplied drawing records a quotation-stage foundation and optional security arrangement. Final footing, ground condition, loading and statutory requirements are project-specific.

01Standard foundation450 × 450 × 600 mm deep; minimum 15 MPa concrete
02Optional baseOptional 200 × 150 mm concrete plinth
03Razor addition500 mm razor flatwrap with 2.24 mm straining wires
04Extended supportExtended support post at 4 m intervals shown on flatwrap drawing
Download isometric source drawing
Specification control

From standard detail to site-specific solution.

The diagrams explain Capstone’s supplied source sheets. Final post lengths, foundations, concrete, loads, ground conditions, slopes, services, razor requirements and statutory compliance are defined for the actual project.

Project enquiry

Need a concrete palisade system and quote?

Send the selected height, approximate metres, razor or plinth requirement, project location, gates and any tender or engineer specification.

WhatsApp